2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 276
Controlled Air Guiding Circuit
Condition for fault identification
Test condition:
AKKS must be initialized.
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
up to 20 sec.
Action in service
1. Check wire from the DME to the AKKS
Fault effect and breakdown warning
Driver information
Warning light:
no external display;
Service instruction
none
2F0F
2F0F – P14C1
Information saved in
DME
Fault code
2F0F – P14C1
Fault text
Radiator blind, self-diagnosis
Fault description
Radiator Shutter Mechanical or Hardware Defect
Condition for fault identification
Test condition:
none
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
none
Action in service
none
Fault effect and breakdown warning