2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 274
Warning light:
none
Service instruction
none
2FA4
2FA4 – P3235
Information saved in
DME
Fault code
2FA4 – P3235
Fault text
Incorrect data record
Fault description
Control Module Monitoring Version Coding Plausibility
Condition for fault identification
Test condition:
Always active
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
none
Action in service
Data programming, of fault remains active re-enter DME
code, if then still active replace the DME
Fault effect and breakdown warning
Driver information
Warning light:
Reduced output
Service instruction
none
2F0D – P300A (DME)
2F0D – P300A
Information saved in
DME
Fault code
2F0D – P300A
Fault text
Radiator blind, activation, (GLF)
Fault description
Controlled Air Guiding Circuit High
Condition for fault identification
Test condition:
AKKS must be initialized.
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry