Saturday, April 25, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 184

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 184

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning

Driver information

Warning light:

No CC message

Service instruction

none

2DED

2DED – P160F

Information saved in

DME

Fault code

2DED – P160F

Fault text

Power management, closed-circuit current violation

Fault description

Powermanagement No-Load Current Error

Condition for fault identification

Test condition:

Standby current violation:

Standby current draw exceeds approved level. Standby

current is calculated only when ISD-BSD communications

are not present – vehicle in sleep mode.

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

Vehicle in sleep mode

Action in service

Conduct energy diagnosis:

Fault effect and breakdown warning

Driver information

Warning light:

CC message ‘High battery discharge when parked’

Service instruction

none

2DE0

2DE0 – P16C8

Information saved in

DME

Fault code

2DE0 – P16C8

Fault text

No message from electric fuel pump