Friday, April 24, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 177

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 177

Monitoring, terminal 15

Fault description

Terminal 15 Sense Circuit Range/Performance

Condition for fault identification

Test condition:

none

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

2DC8

2DC8 – U0101

Information saved in

DME

Fault code

2DC8 – U0101

Fault text

No message from EGS, EGS 1

Fault description

Lost Communication With TCM

Condition for fault identification

Test condition:

EGS detected

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

5 sec.

Action in service

Check CAN link to EGS control module

Fault effect and breakdown warning