Saturday, April 25, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 181

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 181

Condition for fault identification

Test condition:

1. CAN 11 vehicle (E46, E85, E83)

2. No short circuit on the PT CAN

3. LWS1 message initialized

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

5 sec.

Action in service

Check CAN link between LWS and DME

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

2DEB – P160C (DME)

2DEB – P160C

Information saved in

DME

Fault code

2DEB – P160C

Fault text

Power management, vehicle electrical system

Fault description

Powermanagement Overvoltage

Condition for fault identification

Test condition:

Overvoltage with engine running:

Terminal condition: Terminal 15, engine on

Voltage condition:

Voltage in onboard electrical system > 16 V

Condition for fault memory entry

Voltage in onboard electrical system > K_OSPGAPP (16V)

for 10 sec. (debounced in SW)

Action in service

Perform alternator diagnosis.

Fault effect and breakdown warning