2F4B – P165C (DME)
2F4B – P165C
Information saved in
DME
Fault code
2F4B – P165C
Fault text
DME, internal fault: immobilizer data
Fault description
EWS (Electronic Immobilizer) Data, No Available Storage
Possibility
Condition for fault identification
Test condition:
Calibration procedure
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
1
Action in service
Replace DME
Fault effect and breakdown warning