2F4C – U1166 (DME)
2F4C – U1166
Information saved in
DME
Fault code
2F4C – U1166
Fault text
Message EWS-DME incorrect
Fault description
Message Monitoring EWS (Electronic Immobilizer) – Frame
Error
Condition for fault identification
Test condition:
EWS code request
Terminal condition: Terminal 15 on without running engine
Voltage condition:
none
Condition for fault memory entry
2
Action in service
Continue problem diagnosis with CAS
Fault effect and breakdown warning