29DA
29DA – P1396
2010-2020 BMW 128i Convertible (E88) L6-3.0L (N51) WWW.168MOTIVE.COM Page 318
Information saved in
DME
Fault code
29DA – P1396
Fault text
Crankshaft sensor, segment adaptation
Fault description
Crankshaft Position Sensor Segment Timing Plausibility
Condition for fault identification
Test condition:
In the adaptation phases with active overrun injection
deactivation
Terminal condition: Terminal 15, engine on
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
Violation of maximum approved adaptation range
Action in service
Check and replace as indicated: Crankshaft sensor, reluctor
Fault effect and breakdown warning